What is a Cell Based Assay?

A cell based assay uses live cells to quantify biological processes and evaluate cellular responses to various stimuli. These assays provide a more physiologically relevant model compared to biochemical assays that just measure the concentration of the drug induced moiety, such as protein, DNA or RNA. Since cell based assays are conducted in a cellular environment they can mimic disease states, preserve signaling pathways, and model drug responses. The purpose of a cell based assay can be to screen for a final drug candidate to further develop, to define the biological strength of the drug, and to demonstrate, that different manufactured lots are comparable. Cell based assays have become an essential tool in modern biomedical research and drug development, offering insights into the mechanism of action of a drug, the cellular responses underlying disease mechanisms and developing effective treatments (1,2).

Need a cell-based assay developed and validated to GMP?

Request a quoteSchedule a call with a scientist

Why have a cell based assay for drug discovery and development?

You want an assay that mimics the full function that your drug is required to have a clinical effect. The assay defines the strength of manufactured lots and measures the functional stability and degradation of the drug upon storage. This allows an estimate of when new lots are required.to be manufactured.

Key Features and Advantages of Cell Based Assays

1 Biological Relevance: They offer a more accurate representation of how compounds might behave in living organisms compared to biochemical assays. They provide complex and biologically relevant data.
2 Versatility: Cell based assays can be used to assess various cellular functions, including cytotoxicity, proliferation, migration, invasion, and signaling pathways. They assess multiple compound characteristics simultaneously.
3 Applications: They are widely used in drug discovery, toxicity screening, and biomedical research. They enable early identification of promising drug candidates. At later stages of the project, the assays are used for.comparable lot release of manufactured lots, stability, formulation, etc.
4 High-Throughput Capability: Many cell based assays can be adapted for high-throughput screening, allowing for efficient testing of large numbers of compounds

Some Types of Cell Based Assays

Cell based assays have many purposes. Examples are shown below.
• Cytotoxicity assays
• Cell proliferation assays
• Reporter gene assays
• Cell signaling assays
• Angiogenesis assays
• Cell migration, chemotaxis and invasion assays

What is a GMP cell based assay?

Any assay should be accurate and precise in order to derive meaningful conclusions. A typical cell based assay comprises a reference sample and a test sample each at 8 or more concentrations performed in a 96well plate in triplicate or quadruplicate conditions.

What is a current GMP (cGMP) assay?

Current Good Manufacturing Practice (cGMP) combines legally binding but often generalized GMP documents, with current practice and guidance from the FDA. These documents ensue that manufactured lots are safe, and comparable, especially to the lot used for preclinical toxicity studies, and effective for their intended use. Full GMP compliance is required for clinical phase 3 and for registration / commercialization. FDA and European Union (EU) guidances are critical for interpretation of cGMP rules (references 6-8).

Characteristics of a cGMP assay

Issues to satisfy the requirements include –

  • Each drug concentration should be assayed at least in triplicate.
  • A manufactured lot is designated as the refence standard, to be run alongside a test sample.
  • Documented assay parameters are, for example, cell numbers, timing, dosing, method of readout. What are the acceptable limits around each of these parameters?
  • Proof of accuracy and precision.
  • Proof of accurate concentration range and linearity.
  • Robustness, such as, equivalent results with several operators, with multiple pieces of equipment, and with several lots or different vendors for critical regents.
  • Documentation that each assay was performed correctly, “fit for purpose”. What equipment and reagents were used? Were the equipment and reagents within specification?
  • Document that analyst procedures were performed properly for each assay.
  • Records are CRF21 compliant (3). This document defines the criteria under which electronic records and electronic signatures are considered trustworthy, reliable, and equivalent to paper records., Initial raw data is saved contemporaneously dated and password protected. It cannot be altered .Transfer of data from an instrument to an Excel spreadsheet is documented to be unaltered, etc.

Designing a Cell based Assay

Issues to consider are:

  • The assay must be a biological response, a live cell has to produce an effect
  • Relevant cell type
  • Project phase relevant, when is FDA GMP compliance required?
  • Methodology – precise, accurate, stable
  • Dose response, ratio of maximum signal to no-drug signal
  • A ratio of 2 to 3 is acceptable only if the replicates at each drug concentration are very tight and there is unequivocal dose response.
  • Convenient – relatively easy for an analyst to follow
  • Urgency, when is the method needed?
  • Cost

Selecting Relevant Cells

Choosing the appropriate cell type lies at the heart of effective assay design. Cells selected for the assay should mirror the disease or target under investigation. A drug intended for human clinical trials and commercialization should preferably use a human cell line. For example, a cancer therapeutic should use the relevant cancer cell type. A neurological drug should preferably use the relevant neural cell type.

Explore our expert cell-based assay services deliver reliable results for your drug development needs. Learn more here.

Methodology Issues

A screening of prospective cell types may be necessary to obtain a good assay with a strong signal and convenient method. The method has to consider cell numbers, drug concentrations, timing, equipment, ease, readout, signal to noise ratio and other parameters. Marin Biologic is experienced with all these issues. We use quantitative Polymerase Chain reaction (qPCR) for gene expression, ELISA and Western analysis for specific protein expression, flow cytometry for various cell based readouts, radioisotopes and other methods.
Improving Assay Conditions: Fine-tuning assay conditions, such as cell density, incubation time, and media composition, is pivotal. These parameters influence the reliability and relevance of results and must be meticulously employed to ensure reproducibility.
Dose-Response Analysis: Understanding the relationship between compound concentration and cellular response is imperative. Conducting dose-response analyses shows the concentration at which the compound is most effective.
Reference Standard: Establishing a Reference Standard, even if on an interim basis, is important in order to identify drift in assay results and for comparison of different lots of manufactured product. Stability of the Reference Standard during storage should be investigated.
Controls: The positive control is the Reference Standard (see above). Negative controls may include the excipient or buffer matrix alone without drug, degraded drug and other similar drugs that are in the pipeline of the drug manufacturer.

Cost

Cost is an issue, especially with small companies striving to get their first product approved for commercialization. As an example, an assay utilizing a radioactive isotope may offer an excellent method but with extra expense and difficulties, but a less costly nonradioactive method may be acceptable.

Data analysis

Most cell based assays have data that conform to a 4 parameter (4P) or sigmoid statistical analysis (4). The result of such analysis is the drug potency, the EC50 value, the concentration at the 50% point of the dose response curve. For a new manufactured drug, the lot release result is the relative Potency (RP) of the new lot EC50 relative to the Reference Standard EC50

RP = [EC50Reference / EC50Test].

In the 4P example below, Reference Standard (POS1) and the Test Sample (POS2) have comparable EC50 values.

Figure 1. Example of 4P fits of experimental data. The data for each curve, Reference (Position 1) and Test (Position 2) conform to 4P fits with EC50 values at about 1.4 ng/mL.

Some drugs cannot be manufactured at a dose strong enough to result in a top asymptote or plateau required for 4P analysis, such as Adeno Associated Virus (AAV) vectors. In such cases a parallel line analysis may be appropriate (4). Results of measuring Standard and Test samples are selected that fit a straight line on a semi log scale. In the figure below, the two lines are parallel (criteria must be developed to document this). Displacement of test (blue) from standard (red), in this case to the left, indicates that the Test sample is more potent, requires less material to achieve the same response. The Relative Potency (RP) of the Test sample is given by the ratio of the two x-intercepts.

RP = [(x-intercept Reference ) / (x-intercept Test)]

In this example, the RP is 10.01.

Figure 2. Example of a Parallel Line Analysis of responses of a Reference Standard (Top) and a Test Sample (Bottom) A virus vector was used to transfect a host cell at seven different viral genomes per cell (vg/cell). After an incubation period, the protein product of the encoded gene was measured in ng/mLin cell supernatants by ELISA. The vg/cell and ng/mL values were plotted on a log-log scale. The statistical sottware picked the values that fit a straight line, in this case all seven non zero values for both samples The Relative Potency (RP) of the Test sample is given by

RP = [Testx-intercept / Referencex-intercept ]

The results show that the two samples have very similar potencies, [-4.48 / -4.96 ],
an RP of 0.903.

Acceptance Criteria

1. Drug chemical properties.
If the drug weight or concentration is to be verified at the testing site after receipt from the manufacturer, acceptable ranges should be specified.

2. Acceptable ranges for critical parameters of the assay. For a GMP assay, acceptable range for parameters such as cell number, length of assay time, concentration of reagents, and time limits of the readout method should be measured and documented in the SOP.

3. Assay acceptance criteria. Each assay should demonstrate “Fit for Purpose”.
Issues that are usually investigated and documented in the SOP and for each assay may include:

a) Precision of replicate values.
b) R2 fit of the data to the statistically determined dose response data for the Reference Standard and for the Test sample.
c) Parallelism of the Test sample to Reference Standard, to demonstrate that the Test sample is qualitatively similar in biological effect.
d) EC50 value of the Reference Standard in each assay. This tests for any drift in the assay, for example, has the cell response changed.

4. Drug product acceptance criterion. The drug test sample may have acceptance criteria, PASS / FAIL, based on its Relative Potency relative to Reference Standard assayed on the same plate. Alternatively, the SOP may specify “Report only” to give the company the option of how to set passing criterial.

Full cGMP Assay

A cGMP assay that is acceptable to the FDA will include the following:

1. Standard Operating Procedure (SOP)
2. Protocol that describes the validation study
3. Linearity- accuracy (testing Reference at 50%, 75%, 125% and 150% of the usual concentrations)
4. Parallelism of the Reference and Test dose responses
5. Specificity
6. Ruggedness (more than one operator, equipment and critical reagents)
7. Validation that covers the above in a minimum of three experiments
8. A report that documents the process, with Quality Assurance oversight

FDA documents are:

  • 21 Code of Federal Regulations, 21 CFR) 610, Characterization for Product Release, reference 5
  • 2011 Guidance, Process Validation: General Principles and Practice, reference 6
  • 2015 Guidance Analytical Procedures and Methods Validation, reference 7
  • 2023 Potency Assurance for Cellular and Gene Therapy Products, reference 8

Marin Biologic can help you with this decision and how to communicate with the FDA.

Explore our expert GMP cell-based assay services deliver reliable results for your drug development needs.

Project Development Phase

A full GMP validated assay is necessary at clinical phase 3 and for commercialization, although many companies choose to develop a robust assay at phase 1 or 2. Such robustness may be lessened at preclinical and clinical phase 1 and 2 of the project. However, an SOP and documented precision, accuracy and reproducibility is necessary.

Decisions made early and presented to the FDA tend to dominate later development. The effort to make significant changes in the method requires considerable effort in resources and cost, and a big headache for your Quality Assurance department and for your interactions with the FDA.

References

  1. Wei et al. A review for cell-based screening methods in drug discovery
  2. The role of cell-based assays for drug discovery
  3. FDA 21 Code of Federal Regulations (21 CFR) Part 11, Electronic records
  4. Statistical analysis with Prism
  5. FDA code 21 CFR 610, Characterization for Product Release.
  6. General guidance for potency assays is given in The 2011 FDA Guidance, Process Validation: General Principles and Practices,
  7. 2015 Analytical Procedures and Methods Validation
  8. 2023 Potency Assurance for Cellular and Gene Therapy Products

 

Drug Discovery & Development Assays Offered by Marin Biologic Laboratories